U25339-J-Z126-1-7600 13
Controls and indicators Control panel on the Business Server cabinet
Information is displayed on the LCD display in the following format:
Meanings:
Line Display field Display Meaning
Line 1 Maintenance
mode
none User mode
CE Maintenance mode
CM Hot system maintenance mode
Test mode none Normal mode
T Test mode
Cluster status Pnnn S130 switched off: P000
P codes during the switching on and initial-
ization phase as well as when switching off:
P001 to P379
DOWN Display for the output of a WRITE-CONSOL
message (e.g. SHUTDOWN COMPLETED)
RUN CPUs in RUN status
WAIT CPUs in WAIT status
STOP CPUs in STOP status
LOAD IPL is being executed
Line 2 FLAG code none Normal state
FFFFFFFFFFFFFFFF Message or error code:
this display is for the purposes of the service
department.
FFFFFFFFFFFFFFFF
CC C CCCC
CM
CE
T
Pnnn
DOWN
STOP
WAIT
RUN
LOAD
Line 1
Line 2
FFFFFFFFFFFFFFFF
Displays in line 1
Displays in line 2
STATUS